Halvard Pump Works
Centrifugal and diaphragm pumps for water, process and chemical duty — every curve tested, every motor matched.
HV 1.5-8 vertical sump pump, 1,750 RPM
Model: HV-1.5-8-17
Vertical cantilever sump pump: the shaft is supported by two bearings above the mounting plate, with no bearings or seals below the liquid, so it can run dry and handle solids. Cast-iron casing and column, semi-open impeller, suction strainer, NEMA C-face TEFC premium-efficiency motor.
Specifications
| Size & construction | |
|---|---|
| Size | 1.5-8 |
| Discharge size (in) | 1½ |
| Discharge connection | NPT threaded |
| Rated speed | 1,750 RPM |
| Impeller | Semi-open |
| Impeller diameter, maximum | 8 in(203 mm) |
| Impeller diameter, minimum trim | 6 in(152 mm) |
| Wetted materials | ASTM A48 Class 30 cast iron, 416 SS shaft |
| Maximum solids size | 3/4 in(19 mm) |
| Maximum liquid temperature | 180 °F(82.2 °C) |
| Installation | |
| Setting depth, as quoted | 36 in(914 mm) |
| Setting depths available | 24 in, 36 in, 48 in, 60 in |
| Mounting plate (square) | 18 in(457 mm) |
| Minimum submergence above inlet | 6 in(152 mm) |
| Minimum pit depth | 42 in(1,067 mm) |
| Weight with motor, as quoted | 197 lb(89.4 kg) |
| Hydraulics, maximum impeller | |
| Flow at BEP | 60 GPM(13.6 m³/h) |
| Head at BEP | 54.3 ft(16.6 m) |
| Efficiency at BEP (%) | 45 |
| Shutoff head | 66.2 ft(20.2 m) |
| Maximum flow (end of curve) | 78 GPM(17.7 m³/h) |
| NPSH required at BEP | 2 ft(0.61 m) |
| Maximum power, water (end of curve) | 2.12 HP(1.58 kW) |
| Calculated performance | |
| Shaft power at BEP | 1.83 HP(1.36 kW) |
| Head rise to shutoff (%) | 22 |
| Preferred operating region, from | 42 GPM(9.54 m³/h) |
| Preferred operating region, to | 72 GPM(16.4 m³/h) |
| Motor | |
| Standard motor rating | 3 HP(2.24 kW) |
| Motor frame | 182T |
| Motor check | Non-overloading |
| Max. specific gravity, non-overloading | 1.42 |
Related products
Standard motor
Images
Performance curves
- Maximum impeller
- Intermediate impeller
- Minimum impeller
- Maximum impeller
- Minimum impeller
- Standard motor rating
Downloads
- HV Vertical Sump Pumps — Installation, Operation & MaintenanceInstallation manual · 50 KB
- ISO 9001:2015 certificate, Fort Wayne plantCertificate · 46 KB