Halvard Pump Works
Centrifugal and diaphragm pumps for water, process and chemical duty — every curve tested, every motor matched.
HV 3-9 vertical sump pump, 1,750 RPM
Model: HV-3-9-17
Vertical cantilever sump pump: the shaft is supported by two bearings above the mounting plate, with no bearings or seals below the liquid, so it can run dry and handle solids. Cast-iron casing and column, semi-open impeller, suction strainer, NEMA C-face TEFC premium-efficiency motor.
Specifications
| Size & construction | |
|---|---|
| Size | 3-9 |
| Discharge size (in) | 3 |
| Discharge connection | ASME B16.1 Class 125 FF flanged |
| Rated speed | 1,750 RPM |
| Impeller | Semi-open |
| Impeller diameter, maximum | 9 in(229 mm) |
| Impeller diameter, minimum trim | 7 in(178 mm) |
| Wetted materials | ASTM A48 Class 30 cast iron, 416 SS shaft |
| Maximum solids size | 1 in(25.4 mm) |
| Maximum liquid temperature | 180 °F(82.2 °C) |
| Installation | |
| Setting depth, as quoted | 48 in(1,219 mm) |
| Setting depths available | 24 in, 36 in, 48 in, 60 in |
| Mounting plate (square) | 24 in(610 mm) |
| Minimum submergence above inlet | 9 in(229 mm) |
| Minimum pit depth | 54 in(1,372 mm) |
| Weight with motor, as quoted | 321 lb(146 kg) |
| Hydraulics, maximum impeller | |
| Flow at BEP | 240 GPM(54.5 m³/h) |
| Head at BEP | 68.7 ft(20.9 m) |
| Efficiency at BEP (%) | 62 |
| Shutoff head | 83.8 ft(25.5 m) |
| Maximum flow (end of curve) | 312 GPM(70.9 m³/h) |
| NPSH required at BEP | 4.7 ft(1.43 m) |
| Maximum power, water (end of curve) | 7.78 HP(5.8 kW) |
| Calculated performance | |
| Shaft power at BEP | 6.72 HP(5.01 kW) |
| Head rise to shutoff (%) | 22 |
| Preferred operating region, from | 168 GPM(38.2 m³/h) |
| Preferred operating region, to | 288 GPM(65.4 m³/h) |
| Motor | |
| Standard motor rating | 10 HP(7.46 kW) |
| Motor frame | 215T |
| Motor check | Non-overloading |
| Max. specific gravity, non-overloading | 1.29 |
Related products
Standard motor
Images
Performance curves
- Maximum impeller
- Intermediate impeller
- Minimum impeller
- Maximum impeller
- Minimum impeller
- Standard motor rating
Downloads
- HV Vertical Sump Pumps — Installation, Operation & MaintenanceInstallation manual · 50 KB
- ISO 9001:2015 certificate, Fort Wayne plantCertificate · 46 KB